Voltage Controlled Switch
Active High or Active Low
10 - 60 V / 30 amp

Application

Used for simple on / off control of devices that require user adjustment of the turn ONn and OFF voltage. Examples are backup generator control, fluid level control, simple charge controller, simple LVD relay control, Battery Vent Controller etc.


Model: VCS-1AH

The most versatile controller available!

Simple Applcation Diagrams

Features

  • Wide Voltage range
  • Fused and Transient protected
  • Adjustable high and low setpoints
  • High Reliability
  • Available as Active High and Active Low.

Basic Operation

Solar Converters Inc. Voltage Controlled Switch is a simple power relay switch which has user adjustable voltage setpoints. Normally the relay is not powered, connecting the common terminal (C) to the normally closed (NC) terminal.

The Active High unit monitors the incoming voltage and if it goes over the "high" setpoint for 3 seconds, the power relay will switch on, connecting the common terminal (C) to the normally open (NO) terminal.

Once the relay is on, the unit monitors the incoming voltage and if it goes below the "low" voltage setpoint for 3 seconds, the unit will turn off the power relay, connecting the common (C) terminal to the normally closed (NC).

Active Low operation is identical to the Active High listed above BUT the relay operation is opposite.

In Active Low operation, the unit monitors the incoming voltage and if it goes below the "low" setpoint for 3 seconds, the power relay will switch on, connecting the common terminal (C) to the normally open (NO) terminal.

Once the relay is on, the unit monitors the incoming voltage and if it goes above the high voltage setpoint for 3 seconds, the unit will turn off the power relay, connecting the common (C) terminal to the normally closed (NC).

Features

  • Single unit 12, 18, 24, 36 and 48 V operation
  • Easy to setup, setpoints have a 1/10 th. scale factor. To set 12 V, set the setpoint to 1.2V

Electrical Specifications

Nominal Voltage (V) 12 18 24 36 48
Max Output (A)
Basically rating of 30 amp relay
30 30 30 15 03
Maximum Voltage (V) 63
Minimum Voltage (V) 10
Self Consumption
Quiescent (ma) 17 17 17 17 17
Relay on (ma) 75 57 47 37 32

Standard Delay on action is 3 seconds low, 1 second high
Delay of 0.1 sec to 45 Seconds are available. Please specify at time of ordering
Default relay position on startup between voltage setpoint - Relay Off

Mechanical Specifications

Weight:

  • 0.3 lbs. approx.

Size:

  • 4.125" x 2.8" x 2" open frame as shown above

Available in enclosure with 1/2" conduit knockouts Model: VCS-2AL

Connections:

  • Power:
  • Eurostyle Terminal Strip #6 AWG

Operating Temperature:

  • -40 to 60 deg. C

Humidity:

  • 0 - 90 % non-condensing

Mechanical Drawing: Click here for picture

Note: In the interest of continuous product improvement specifications subject to change without notice.

Order Model No:

  • VCS-1AH Active High
  • VCS-1AL Active Low
  • VCS-2AH Active High
  • VCS-2AL Active Low

March 2002