96 V @ 6 amp Linear Current Booster/Pump Driver
Application
Used to control and power a DC motor from a solar panel. The unit prevents stalling of the motor
under less than full sun condition. The power of the sun is transformed to the motor
running conditions so as the sun goes down the motor slows down instead of stalling. Conversely, or
as the sun comes up the motor starts running much earlier instead of staying stalled
for hours when it could be running. This translates into more running time of the motor
where it spends a lot of time working instead of stalled doing no work.
Model: PPT 90-6
Features
- Voltage Limited Output
- Greatly increases water flow, even under reduced sunlight conditions (over 40% likely)
- Transient Protected on the input and output
- Float Switch input for on/off control
- Ultra High Efficiency >94 %
- Weatherproof NEMA enclosure
Electrical Specifications
| Nominal Voltage (V) |
96 |
| Nominal PV Input (V) |
96 |
| Maximum PV Input (V) |
160 |
| Maximum Output Voltage (v)** |
99 |
| Maximum Output (A) |
6 |
Maximum Output (A) short term - 10 sec |
20 |
| Efficiency |
>94% |
** Special units have a suffix of M XX after the par number. The maximum output voltage
of the pump driver is XX. For example PPT 90-6 M24 will power a 24 V motor from a
nominal 96 V solar panel. Note that the motor current increase by the ratio
of approx. 85/24. Thus a 1 amp 48 V nominal solar panel will power the 24 V motor
at approx. 3.5 Amps.
Mechanical Specifications
Weight:
Size:
- 4.5" X 2.5" X 2" nominal, resembling a junction box with mounting feet
Operating Temperature:
Humidity:
Connections
- Power: PV and Load
-
- 6 inch # 16 AWG flying leads
-
- Input: Red = PV +, Black = PV -
-
- Output: White = Pump +, Blue = Pump -
- Signal: float switch, 12/24 V select
-
- 6 inch # 24 flying leads yellow: connect to PV - = OFF for float switch operation
-
- 6 inch # 24 flying leads purple: connect to PV - = 24 V operation disconnected = 12 V operation
-
- 6 inch # 24 flying leads red / black: Output Current Sense scaled at 50 mv = 10 A
Application Notes
- This Pump Power Tracker(TM) is quite capable of putting out over 15 amps into a stalled load even from a single 30 watt 4.5 amp panel. It is recommended that a fuse or overtemperature switch matched to your pump motor be incorporated in the system to protect your pump or motor.
- Float switch operation draws microamps of current, i.e. small wire gauge, allowing long distance runs between float switches / holding tanks, and PV / pump driver without the need to string long lines of heavy gauge wire.
- Unit is a true 6 amp unit, all necessary derating already accounted for.
- As with all electronics, it is recommended the unit not be mounted in direct sunshine.
- Solar panel or energy limited input only.
- Output fuse required. Bussman KAB-10 is recommended.
Mechanical Drawing: Click here for picture
Note: In the interest of continuous product improvement, specifications subject to change without notice.
Order Model No: PPT 90-6
PPT 90-6 MXX for different motor voltage where XX is the max. motor voltage
March 2002
|