60 V @ 10 amp Constant Voltage Pump Driver


Application

Used to keep your Pump voltage constant as the battery discharges from 29 to 22V. Contains integral Fusing, LVD and Float Switch Control.

As your battery discharges your pump slows down and you lose performance, water flow and pumping head. This regulator takes your battery voltage, irrespective of what it is, and produces a constant "full charge" voltage which keep pumps and motors at full output and your system at optimum performance. This is married to an LVD and a float switch control with a fused battery connection for a complete low cost pumping controller.


Model: CVP 60- 10

Picture Not Availible

Features

  • Low Cost
  • High Performance
  • Rugged boost voltage design
  • Ideal for battery backed submersible pumping systems maximizes water output and head
  • Available in NEMA 3R enclosure (raintight)
  • Used battery, integral LVD and Float Switch Control
  • Very high efficiency >92 %, 94 % typical

Electrical Specifications

Input Voltage (V) 22 - 32
Lead acid assumed 24
Low Voltage
disconnect (ON)
Time delay
1 second
23.8V
Low Voltage
disconnect (OFF)
Time delay
1 second
22.0V
Float Switch Control Works even if power boost broken. Connect
yellow wire to Black to turn pump off.
Output Voltage (V) +\- 2%
adjustable by
internal POT
60.0
Output Current (Amps) 10.0
Current Limited * 11.0
Input Fuse Automotive Style: 25 A LittelFuse ATC-25 or equiv.
Quiescent current 20 mA
Transient Protection All Inputs and Outputs and common mode
Efficiency 92 - 96 % depending on loading and state of charge


Mechanical Specifications

Enclosure:

  • Raintight NEMA 3R enclosure
Dimensions:
  • 10" X 8" X 4" nominal
Weight:
  • approx. 6 lbs.
Temperature Range:
  • -40 deg C to 50 deg C
  • It is recommended, as with all electronics, that the unit not be placed in direct sunshine
Terminations:
  • Internal Eurostyle Terminal Strip
  • Power #12 AWG
  • Signal Leads #20
Humidity:
  • N/A weatherproof

Mechanical Drawing: Click here for picture

Note: In the interest of continuous product improvement, specifications subject to change without notice.

Order Model No:

CVP 60-10

March 2002